mirror of
https://github.com/arduino/Arduino.git
synced 2025-01-20 09:52:13 +01:00
77179d78d0
From the data sheet TXCOMP is only set after a stop or repeated start and address change, but EOSACC is set for a stop or repeated start when the address remains the same. This change removes the check for TXCOMP when not idle, to support repeated starts for both RX and TX.