This module will periodically update values of stabilization PID settings
depending on configured input control channels. New values of stabilization
settings are not saved to flash, but updated in RAM. It is expected that the
module will be enabled only for tuning. When desired values are found, they
can be read via GCS and saved permanently. Then this module should be
disabled again.