- both CC serial ports are now disabled by default (no telemetry);
- serial ports now have DSM2, DSMX (10bit) and DSMX (11bit) options;
- ReceiverGroups now have DSM (MainPort) and DSM (FlexiPort) options.
For DSM2 protocol there is an explicit resolution bit in the stream, so
the DSM2 should be selected. For DSMX there is no such bit, and user
should choose the resolution from the list configuring the spektrum port.
ReceiverGroups have single DSM option which is handled by the same driver.
Downside: this implementation saves received frame first, unrolls by the
end of frame. This should be ok, but may be improved by unrolling channels
on the fly in the rx callback.
Another minor difference is that a ChannelGroup is now bound to port:
DSM (MainPort) or DSM (FlexiPort). This was considered as acceptable
solution in order to not have 6 DSM options for each ChannelGroup and
even more in case of new DSM protocol variations.
Known problem: it is not possible to choose same protocols like
DSM2/DSM2 for two ports. It can be enabled by adding an exception to
common rule, though.
The DSMX throttle channel misbehavior (zero value) is not treated
specially yet. It should trigger the failsafe being out of bounds.
More info and data dumps are required to handle this properly.
TelemetrySettings object removed (saved 200+ bytes of RAM). Telemetry
port speed moved to the HwSettings object. Added GPS port speed setting.
GCS code updated to reflect changes and support both fields.
Besides of knob PID tuning it is now possible to use throttle channel
to ramp-shape PID coefficients. This can be used to lower some PIDs on
VTOL while sinking to prevent wobble.
To use the feature select throttle as control input, choose throttle
range max and min values, assign the instance to particular PID
coefficient and define a range for it. When throttle is lower than
defined throttle range min value (or higher than max), then min and max
PID values will be used accordingly. Changing throttle from throttle
min to max will linearly scale PID value.
Note that it is possible to set MinPID > MaxPID. In that case increasing
control input value will decrease the PID coefficient.
Up to 3 independent instances can be configured. The number can be
increased changing the UAVO definition, but at the cost of extra RAM.
This module will periodically update values of stabilization PID settings
depending on configured input control channels. New values of stabilization
settings are not saved to flash, but updated in RAM. It is expected that the
module will be enabled only for tuning. When desired values are found, they
can be read via GCS and saved permanently. Then this module should be
disabled again.
them symbolic constants.
- A timeout is 0
- A missing driver is 65534
- An invalid channel is 65535
ManualControl: Make it deal with the values explicitly. A timed out value
should not be treated like a minimum duration signal. Instead it does not
updated the scaled value but marks the data window as invalid to trigger the